Testo 350 Flue Gas Analyzer
Testo 350 Flue Gas Analyzer that provides 100% accurate result and Tolls Bangladesh it's providing with the best price in Bangladesh.
Model: Testo 350 Flue Gas Analyzer
Testo 350 Flue Gas Analyzer Ideal for professional exhaust gas analysis and industrial emission measurements and that provides the rugged and reliable results to test point.
The Testo 350 exhaust gas analyzer is a rugged piece of kit designed to meet the demands of a variety of different measuring and analysis applications. It is also excellently suited for complex data compilation.
Always the Testo product that you will get from Tools Bangladesh. Order from here if you need it and get the facility for delivery anywhere in Bangladesh for free.
Key Features: Testo 350 Flue Gas Analyzer
- Increased measurement range for unlimited measurements even when gas concentrations are higher
- Easy-to-change gas sensors and easy access to wearing parts
- Sealed housing with built-in impact protection for use in harsh conditions
- Easy operation of the analyzer unit via Control Unit or easy mission software (both products available separately)
Specifications: Testo 350 Flue Gas Analyzer
Temperature - NTC | |
---|---|
Measuring range |
-20 to +50 °C |
Accuracy |
±0.2 °C (-10 to +50 °C) |
Resolution |
0.1 °C (-20 to +50 °C) |
Ambient temperature probe
Temperature - TC Type K (NiCr-Ni) | |
---|---|
Measuring range |
-200 to +1370 °C |
Accuracy |
±0.4 °C (-100 to +200 °C) ±1 °C (-200 to -100.1 °C) ±1 °C (200.1 to +1370 °C) |
Resolution |
0.1 °C (-200 to +1370 °C) |
Temperature - TC Type S (Pt10Rh-Pt) | |
---|---|
Measuring range |
0 to +1760 °C |
Accuracy |
±1 °C (0 to +1760 °C) |
Resolution |
0.1 °C (0 to +1760 °C) |
Differential Pressure - Piezoresistive | |
---|---|
Measuring range |
-40 to +40 hPa -200 to +200 hPa |
Accuracy |
±1.5 % of mv (-40 to -3 hPa) ±1.5 % of mv (+3 to +40 hPa) ±0.03 hPa (-2.99 to +2.99 hPa) ±1.5 % of mv (-200 to -50 hPa) ±1.5 % of mv (+50 to +200 hPa) ±0.5 hPa (-49.9 to +49.9 hPa) |
Resolution |
0.01 hPa (-40 to +40 hPa) 0.1 hPa (-200 to +200 hPa) |
Absolute Pressure | |
---|---|
Measuring range |
600 to +1150 hPa |
Accuracy |
±10 hPa |
Resolution |
1 hPa |
Flue gas O₂ | |
---|---|
Measuring range |
0 to +25 Vol.% |
Accuracy |
±0.8% of fsv (0 to +25 Vol.%) |
Resolution |
0.01 Vol.% (0 to +25 Vol.%) |
Reaction time t₉₀ |
20 s (t₉₅) |
Flue gas CO (with H₂-compensation) | |
---|---|
Measuring range |
0 to +10000 ppm |
Accuracy |
±5 % of mv (+200 to +2000 ppm) ±10 % of mv (+2001 to +10000 ppm) ±10 ppm (0 to +199 ppm) |
Resolution |
1 ppm (0 to +10000 ppm) |
Reaction time t₉₀ |
40 s |
H₂ only as an indicator
Flue gas COlow | |
---|---|
Measuring range |
0 to 500 ppm |
Accuracy |
±5 % of mv (+40 to +500 ppm) ±2 ppm (0 to +39.9 ppm) |
Resolution |
0.1 ppm (0 to +500 ppm) |
Reaction time t₉₀ |
40 s |
H₂ only as an indicator
Flue gas NO | |
---|---|
Measuring range |
0 to +4000 ppm |
Accuracy |
±5 % of mv (+100 to +1999 ppm) ±10 % of mv (+2000 to +4000 ppm) ±5 ppm (0 to +99 ppm) |
Resolution |
1 ppm (0 to +4000 ppm) |
Reaction time t₉₀ |
30 s |
Flue gas Nolow | |
---|---|
Measuring range |
0 to +300 ppm |
Accuracy |
±5 % of mv (+40 to +300 ppm) ±2 ppm (0 to +39.9 ppm) |
Resolution |
±0.1 ppm (0 to +300 ppm) |
Reaction time t₉₀ |
30 s |
Flue gas NO₂ | |
---|---|
Measuring range |
0 to +500 ppm |
Accuracy |
±5 % of mv (+100 to +500 ppm) ±5 ppm (0 to +99.9 ppm) |
Resolution |
0.1 ppm (0 to +500 ppm) |
Reaction time t₉₀ |
40 s |
Flue gas SO₂ | |
---|---|
Measuring range |
0 to +5000 ppm |
Accuracy |
±5 % of mv (+100 to +2000 ppm) ±10 % of mv (+2001 to +5000 ppm) ±5 ppm (0 to +99 ppm) |
Resolution |
1 ppm (0 to +5000 ppm) |
Reaction time t₉₀ |
30 s |
Flue gas degree of effectivity, Eta (calculated) | |
---|---|
Measuring range |
0 to +120 % |
Resolution |
0.1 % (0 to +120 %) |
Flue gas loss (calculated) | |
---|---|
Measuring range |
0 to +99.9 % |
Resolution |
0.1 % (0 to +99.9 %) |
Flue gas dewpoint (calculated) | |
---|---|
Measuring range |
0 to +99.9 °Ctd |
Resolution |
0.1 °Ctd (0 to +99.9 °Ctd) |
Flue gas CO₂ calculation (calculated from O₂) | |
---|---|
Measuring range |
0 to CO₂ max |
Accuracy |
calculated from O₂ ±0.2 Vol.% |
Resolution |
0.01 Vol.% |
Flue gas H₂S | |
---|---|
Measuring range |
0 to +300 ppm |
Accuracy |
±5 % of mv (+40 to +300 ppm) ±2 ppm (0 to +39.9 ppm) |
Resolution |
0.1 ppm (0 to +300 ppm) |
Reaction time t₉₀ |
35 s |
Flue gas CO₂ - NDIR | |
---|---|
Measuring range |
0 to +50 Vol.% |
Accuracy |
±0.3 Vol.% + 1 % of mv (0 to 25 Vol.%) ±0.5 Vol.% + 1.5 % of mv (>25 to 50 Vol.%) |
Resolution |
0.01 Vol.% (0 to 25 Vol.%) 0.1 Vol.% (> 25 Vol.%) |
Reaction time t₉₀ |
10 s |
Velocity / Volume flow | |
---|---|
Measuring range |
0 to +40 m/s |
Resolution |
0.1 m/s (0 to +40 m/s) |
Methane (CH₄) | |
---|---|
Measuring range |
100 to 40000 ppm |
Accuracy |
< 400 ppm (100 to 4000 ppm) < 10 % of mv (> 4000 ppm) |
Resolution |
10 ppm |
Min. O₂ requirement in flue gas |
2 % + (2 x mV methane) |
Reaction time t₉₀ |
< 40 s |
Response factor |
1 |
Lower explosion limit (LEL) must be adhered to.
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.
Propane (C₃H₈) | |
---|---|
Measuring range |
100 to 21000 ppm |
Accuracy |
< 400 ppm (100 to 4000 ppm) < 10 % of mv (> 4000 ppm) |
Resolution |
10 ppm |
Min. O₂ requirement in flue gas |
2 % + (5 x mV propane) |
Reaction time t₉₀ |
< 40 s |
Response factor |
1.5 |
Lower explosion limit (LEL) must be adhered to.
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.
Butane (C₄H₁₀) | |
---|---|
Measuring range |
100 to 18000 ppm |
Accuracy |
< 400 ppm (100 to 4000 ppm) < 10 % of mv (> 4000 ppm) |
Resolution |
10 ppm |
Min. O₂ requirement in flue gas |
2 % + (6.5 x mV butane) |
Reaction time t₉₀ |
< 40 s |
Response factor |
2 |
Lower explosion limit (LEL) must be adhered to.
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.
General technical data | |
---|---|
Weight |
4800 g |
Dimensions |
330 x 128 x 438 mm |
Operating temperature |
-5 to +45 °C |
Product-/housing material |
ABS |
Protection class |
IP40 |
Product colour |
Black |
Connectable probes |
1 x combustion air temperature probe; 1 x flue gas probe; 1 x temperature probe; 1 x differential pressure |
Battery type |
lithium batteries |
Battery life |
5 h |
Power supply |
AC mains unit 100V to 240V (50 to 60 Hz) |
DC electric tension input |
11V to 40V |
Dewpoint calculation |
0 °Ctd; 99 °Ctd |
Max. dust load |
20 g/m³ dust in flue gas |
Max. neg. press./flue gas |
-300 mbar |
Max. pos. press./flue gas |
50 mbar |
Trigger input |
Voltage 5 to 12 Volt (rising or trailing edge) pulse width > 1 sec load: 5 V/max, 5 mA, 12 V/max. 40 mA |
Max. humidity load |
70 °C dewpoint temperature |
Hose length |
16.2 m (corresponds to 5 probe hose extensions) |
Pump flow |
1 l/min. with through-flow monitoring |
Maximum memory |
250,000 readings |
Interface |
data bus; Bluetooth®; USB; IR/IRDA interface; Mains connection; trigger input; Differential Pressure; probe input/ probe inputs; DC-voltage input; dilution gas inlet for measurement range extension |
Storage temperature |
-20 to +50 °C |
Includes: Testo 350 Flue Gas Analyzer
- Testo 350 Flue Gas Analyzer
Accessories: Testo 350 Flue Gas Analyzer
- Testo easy mission software
- Spare thermal paper for the printer, permanent
- Testo fast printer IRDA
- Transport case